Transformer current and efficiency

Transformer current and efficiency

Find the primary current or percentage efficiency from the primary r.m.s. voltage and total secondary real power.

  • 117 bytes
  • COMP mode
01

Worked examples

Example 1

Original exercise. Find the primary current or percentage efficiency from the primary r.m.s. voltage and total secondary real power. Vₚ=200 V; Pₛ=60 W; η=75%; cosφ=1. Iₚ=?

Answer
200×0.4×0.75=60 W.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: η=75/100=3/4; Pₚ=Pₛ/η=60/(3/4)=80 W.
  3. Calculation: Iₚ=Pₚ/Vₚ=80/200=0.4 A.
  4. Conclusion: 200×0.4×0.75=60 W.
Do it on the calculator

Example 2

Original exercise. Find the primary current or percentage efficiency from the primary r.m.s. voltage and total secondary real power. Vₚ=240 V; Pₛ=96 W; Iₚ=0.50 A; cosφ=1. η%=?

Answer
0<80≤100; 120−96=24 W.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: Pₚ=VₚIₚ=240×0.5=120 W.
  3. Calculation: η%=100Pₛ/Pₚ=100×96/120=80%.
  4. Conclusion: 0<80≤100; 120−96=24 W.
Do it on the calculator

Example 3

Original exercise. Find the primary current or percentage efficiency from the primary r.m.s. voltage and total secondary real power. Vₚ=120 V; Pₛ=18 W; η=100%; cosφ=1. Iₚ=?

Answer
120×0.15=18 W.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: η=1 ⇒ Pₚ=Pₛ=18 W.
  3. Calculation: Iₚ=18/120=0.15 A.
  4. Conclusion: 120×0.15=18 W.
Do it on the calculator
02

When to use it

Find the primary current or percentage efficiency from the primary r.m.s. voltage and total secondary real power.

Input order

  • Vₚ / V → Pₛ / W → Iₚ / A → η / %
  • Restart for each problem. Leave the designated unknown empty and press EXE; its preset −1 is the missing-value marker. Enter every known value, including 0EXE when zero is allowed. Zero is different from blank. Used working variables and Ans are overwritten.

Results

  • Iₚ / A
  • η / %
  • All displayed values follow the output order below. A pause requires EXE; the final screen uses AC.

Conditions and limits

  • Input Vₚ>0 V,Pₛ>0 W,Iₚ>0 A,η% with 0<η≤100. Leave exactly Iₚ or η blank. Output only that missing quantity; −1 rejects invalid data or a wrong blank count. Enter 75 for 75%, not 0.75. Add secondary load powers before entering Pₛ. The model assumes single phase and power factor 1, with r.m.s. voltage and current. It does not find turns, phase angles, line losses or three-phase power. Zero load is excluded. Explicit −1 is the reserved missing-value marker. The program sets Norm 1.
  • The finite precision and numeric range of the calculator limit very large, very small or nearly cancelling values.