161Physics · Electrical power

Resistor power: inverse calculation

Resistor power: inverse calculation

Use the constant-resistance model to find one missing operating voltage, resistance or power, followed by the current.

  • 200 bytes
  • COMP mode
01

Worked examples

Example 1

Original exercise. Use the constant-resistance model to find one missing operating voltage, resistance or power, followed by the current. Vᵣ=240 V; Pᵣ=960 W; V=120 V (r.m.s.); R=R₀. P=?, R=?, I=?

Answer
P/Pᵣ=(120/240)²=1/4; P=240 W, R=60 Ω, I=2 A.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: R=Vᵣ²/Pᵣ=240²/960=60 Ω.
  3. Calculation: P=V²/R=120²/60=240 W; I=V/R=120/60=2 A.
  4. Conclusion: P/Pᵣ=(120/240)²=1/4; P=240 W, R=60 Ω, I=2 A.
Do it on the calculator

Example 2

Original exercise. Use the constant-resistance model to find one missing operating voltage, resistance or power, followed by the current. Vᵣ=100 V; Pᵣ=500 W; P=125 W; R=R₀. V=?, R=?, I=?

Answer
I=50/20=2.5 A; 50²/20=125 W.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: R=100²/500=20 Ω.
  3. Calculation: V²=PR=125×20=2500 V²; V≥0 ⇒ V=50 V.
  4. Conclusion: I=50/20=2.5 A; 50²/20=125 W.
Do it on the calculator

Example 3

Original exercise. Use the constant-resistance model to find one missing operating voltage, resistance or power, followed by the current. V=24 V; P=72 W; R>0. R=?, I=?

Answer
IR=3×8=24 V; I²R=9×8=72 W.
Standard solution (without a calculator)
  1. Substitute the conditions, solve the equations, then retain only values satisfying the stated domain.
  2. Equation: P=V²/R ⇒ R=V²/P=24²/72=8 Ω.
  3. Calculation: I=P/V=72/24=3 A.
  4. Conclusion: IR=3×8=24 V; I²R=9×8=72 W.
Do it on the calculator
02

When to use it

Use the constant-resistance model to find one missing operating voltage, resistance or power, followed by the current.

Input order

  • M → Vᵣ / V → Pᵣ / W → V / V → P / W
  • M → V / V → R / Ω → P / W
  • Restart for each problem. Leave the designated unknown empty and press EXE; its preset −1 is the missing-value marker. Enter every known value, including 0EXE when zero is allowed. Zero is different from blank. Used working variables and Ans are overwritten.

Results

  • P / W → R / Ω → I / A
  • V / V → R / Ω → I / A
  • R / Ω → I / A
  • All displayed values follow the output order below. A pause requires EXE; the final screen uses AC.

Conditions and limits

  • M=1: enter rated Vᵣ>0,Pᵣ>0, then operating V,P with exactly one blank; output the missing V/P, R, I. M=2: enter V,R,P with exactly one blank; output the missing value, I. V,P≥0; R>0; all are magnitudes. For AC use r.m.s. values and a purely resistive load. −1: invalid domain or blank count; −2: no finite positive resistance for the specified V,P; −3: V=P=0 leaves R undetermined. Explicit −1 has the same sentinel meaning as a blank. Changing resistance, power factor and circuit topology are outside the model. Identify the correct branch power before entry. V²/R and V²/P can overflow even when a final answer is finite.
  • The finite precision and numeric range of the calculator limit very large, very small or nearly cancelling values.

Sign in to unlock the full programme

Checking access…

The programme code and appendix unlock together.

Checking access…

Sign in to unlock the full programme

Checking access…

The programme code and appendix unlock together.