Coulomb Force: One Unknown
fx-50FH II · COMP · 182 bytes
Find one charge magnitude, separation or electric force, including zero-value cases.
- 182 bytes
- COMP mode
Worked examples
Example 1
Two isolated dust grains, treated as point charges, carry +8 nC and −5 nC. Their separation is 0.12 m. Using k=9×10⁹ N·m²·C⁻², find the force magnitude and state whether they attract or repel.
Answer
Standard solution (without a calculator)
- Identify the unknown and convert all given values to SI units. |q₁|=8 nC=8×10⁻⁹ C; |q₂|=5 nC=5×10⁻⁹ C; r=0.12 m.
- Rearrange the inverse-square law for that one unknown. F=k|q₁q₂|/r².
- Substitute the numbers, retaining the positive root for a distance. F=(9×10⁹)×(8×10⁻⁹)×(5×10⁻⁹)/0.12²=2.5×10⁻⁵ N.
- Substitute the result back into the original law and check its unit and meaning. (2.5×10⁻⁵)×0.12²=3.6×10⁻⁷=k|q₁q₂|.
- Opposite signs give attraction.
Example 2
During an ideal point-charge calibration, a charge of magnitude 1.6 μC is 0.24 m from a second charge. The measured force magnitude is 1.8 N. Find the second charge magnitude in C and μC using k=9×10⁹ N·m²·C⁻². Can its sign be deduced from this force magnitude alone?
Answer
Standard solution (without a calculator)
- Identify the unknown and convert all given values to SI units. |q₁|=1.6 μC=1.6×10⁻⁶ C; r=0.24 m; F=1.8 N.
- Rearrange the inverse-square law for that one unknown. |q₂|=Fr²/(k|q₁|).
- Substitute the numbers, retaining the positive root for a distance. |q₂|=1.8×0.24²/[(9×10⁹)×(1.6×10⁻⁶)]=7.2×10⁻⁶ C=7.2 μC.
- Substitute the result back into the original law and check its unit and meaning. (9×10⁹)×(1.6×10⁻⁶)×(7.2×10⁻⁶)/0.24²=1.8 N.
- A force magnitude alone does not determine the second charge’s sign.
Example 3
Two positive point charges, +6 μC and +8 μC, exert a force of magnitude 1.2 N on each other. Find their separation using k=9×10⁹ N·m²·C⁻², and state whether the force is attractive or repulsive.
Answer
Standard solution (without a calculator)
- Identify the unknown and convert all given values to SI units. |q₁|=6 μC=6×10⁻⁶ C; |q₂|=8 μC=8×10⁻⁶ C; F=1.2 N.
- Rearrange the inverse-square law for that one unknown. r=√(k|q₁q₂|/F).
- Substitute the numbers, retaining the positive root for a distance. r=√[(9×10⁹)×(6×10⁻⁶)×(8×10⁻⁶)/1.2]=√0.36=0.6 m.
- Substitute the result back into the original law and check its unit and meaning. (9×10⁹)×(6×10⁻⁶)×(8×10⁻⁶)/0.6²=1.2 N.
- Equal signs give repulsion.
When to use it
For point charges in vacuum or approximately air, use F=k|q₁q₂|/r² with k=9×10⁹ N·m²·C⁻².
Input order
- A = charge magnitude |q₁| (C); B = charge magnitude |q₂| (C); C = separation r (m); D = force magnitude F (N)
- Enter every known value again on each run.
- At exactly one prompt, type nothing and press EXE. The preset −1 remains as the unknown marker.
- A known zero must be entered as 0EXE; a blank EXE is different. Entering −1 manually is indistinguishable from leaving the field blank.
Reading the result
- The missing charge magnitude (C), separation (m) or force magnitude (N)
- −1: invalid fields or blank count; −2: no physical solution; −3: more than one possible solution. None is a physical answer.
- Record the final result, then press AC. Pressing EXE at the completed program starts another run.
Conditions and limits
- Create and run in COMP, Norm 1; the examples use Deg and empty P1. Angle units do not affect either formula. P1–P4 share 680 bytes.
- Enter charge and force magnitudes ≥0; known distance must be >0. Use the original charge signs separately to decide attraction or repulsion.
- The fixed constant cannot be changed for a dielectric medium. This program does not calculate multi-charge resultants, field vectors, potential or charge redistribution.
- If a known charge is zero, a missing other charge is undetermined when F=0 and impossible when F>0. For an unknown distance, F=0 with nonzero charges has no finite solution; zero charge and zero force leave distance undetermined. Zero charge with F>0 gives no positive distance.
- Use SI units and round only the final answer. Finite precision, cancellation, intermediate underflow or overflow can prevent a valid result for extreme data.