Measured Total Bounds
Measured Total Bounds
Find the possible total of nonnegative items whose individual measurements are rounded to a given unit. Keep the lower endpoint and exclude the upper endpoint.
- 40 bytes
- COMP mode
Worked examples
Example 1
Original practice. Find the possible total interval for A nonnegative items, each rounded to B to the nearest C. A=4; B=12 cm; C=1 cm.
Answer
Standard solution (without a calculator)
- 11.5≤w<12.5 cm
- 4×11.5≤T<4×12.5 cm
- 46≤T<50 cm
- Expand or substitute to verify each equality above.
Example 2
Original practice. Find the possible total interval for A nonnegative items, each rounded to B to the nearest C. A=3; B=0 mL; C=1 mL.
Answer
Standard solution (without a calculator)
- 0≤w<0.5 mL
- 3×0≤T<3×0.5 mL
- 0≤T<1.5 mL
- Expand or substitute to verify each equality above.
Example 3
Original practice. Find the possible total interval for A nonnegative items, each rounded to B to the nearest C. A=250; B=80 g; C=10 g.
Answer
Standard solution (without a calculator)
- 75≤w<85 g
- 250×75≤T<250×85 g
- 18750≤T<21250 g
- Expand or substitute to verify each equality above.
When to use it
Find the possible total of nonnegative items whose individual measurements are rounded to a given unit. Keep the lower endpoint and exclude the upper endpoint.
Input order
- A,B,C
- A=n; B=B; C=C
- Enter every value afresh; blank EXE retains old memory and is not zero. All working variables and Ans may be overwritten.
Output order
- L,U; L≤T<U
- A must be an integer 1–10000, B between 0 and 1000, C one of 0.01,0.1,1,10,100 and B an integer multiple of C. Use one consistent unit. The program does not check invalid counts, rounding units or order. Outputs L,U mean L≤T<U, never an attained maximum. A zero rounded value has physical lower bound zero. It sets Norm 1. After the second output press AC; an extra EXE may rerun the program.
Conditions and limits
- Use COMP and Norm 1; the images use Deg, which does not change this algebra.
- A∈ℤ,1≤A≤10000; 0≤B≤1000; C∈{0.01,0.1,1,10,100}; B/C∈ℤ; L≤T<U
- A must be an integer 1–10000, B between 0 and 1000, C one of 0.01,0.1,1,10,100 and B an integer multiple of C. Use one consistent unit. The program does not check invalid counts, rounding units or order. Outputs L,U mean L≤T<U, never an attained maximum. A zero rounded value has physical lower bound zero. It sets Norm 1. After the second output press AC; an extra EXE may rerun the program.
- Use the original equation to check signs, excluded values and endpoint inclusion. Decimal screens are numerical approximations; preserve exact fractions or radicals in written answers.
Checking access…