Composite Area Measurement Bounds
Composite Area Measurement Bounds
Composite Area Measurement Bounds. Output order: lower bound L, upper bound U
- 162 bytes
- COMP mode
Worked examples
Example 1
An optical mask is a rectangle with a rectangular opening removed. Find the possible area interval from the rounded dimensions. M=1; W=16 cm; H=10 cm; w=5 cm; d=3 cm; q=0.2 cm Find the requested quantities and show a mathematical derivation.
Answer
Standard solution (without a calculator)
- Build the mathematical model and substitute the data.
- u=q/2=0.1 cm; S=WH−wd
- L=15.9×9.9−5.1×3.1=141.6
- U=16.1×10.1−4.9×2.9=148.4
- 141.6<S<148.4 cm²
Example 2
A panel has vertical left and right sides and a sloping upper-right edge. Find the area bounds and the least upper bound of the area. M=2; W=18 m; H=12 m; t=7 m; h=5 m; q=0.5 m Find the requested quantities and show a mathematical derivation.
Answer
Standard solution (without a calculator)
- Build the mathematical model and substitute the data.
- S=[W(H+h)+t(H−h)]/2=177.5 m²
- u=0.25 m; L=177.5+0.25²−0.25×30=170.0625
- U=177.5+0.25²+0.25×30=185.0625
- 170.0625≤S<185.0625 m²; sup S=185.0625 m²
Example 3
A notched sheet must provide more than the stated minimum usable area. Find the full area interval and decide whether the guarantee holds. M=1; W=9 m; H=6 m; w=2.5 m; d=1.5 m; q=0.1 m; S>49 m²? Find the requested quantities and show a mathematical derivation.
Answer
Standard solution (without a calculator)
- Build the mathematical model and substitute the data.
- u=0.05 m; S₀=9×6−2.5×1.5=50.25
- L=50.25−0.05(9+6+2.5+1.5)=49.3
- U=50.25+0.05(9+6+2.5+1.5)=51.2
- 49.3<S<51.2 m² ⇒ S>49 m²
When to use it
Read the conditions, choose the geometric model, then enter the values in the stated order. The program does not interpret a diagram or choose which regions to add or subtract.
Input order
- M=1: A=W (width), B=H (height), C=w (notch: width), D=d (notch: depth)
- M=2: A=W (base width), B=H (left height), C=t (horizontal top length), D=h (right height)
- X=q: rounding unit; v_∈[v−q/2,v+q/2)
- Enter every required value explicitly, including 0. Blank EXE keeps the stored value; it is not an entry of zero.
- The lower endpoint is included only when the interval symbol says so.
Output order
- lower bound L
- upper bound U
- The lower endpoint is included only when the interval symbol says so.
Conditions and limitations
- M∈{1,2}; q>0; C>q/2; D>q/2; A−C>q; B−D>q
- A,B,C,D,q: EXE⇒−1; ClrMemory⇒A=B=C=D=X=Y=M=Ans=0
- Enter every required value explicitly, including 0. Blank EXE keeps the stored value; it is not an entry of zero.
- The lower endpoint is included only when the interval symbol says so.
- Nearly indistinguishable measurement bounds require separate calculation. The dimensions must be independent and share the same rounding unit.
- Each new run may overwrite the working registers and Ans. Enter the known values again.
- Use Deg. Do not round intermediate values; retain exact π expressions in written work.
- Use one length unit; areas use its square. −1 is an error, never an area or a solution set.